Product Details:
|
Name: | Linear Glass Scale | Keyword: | Linear Position Encoder |
---|---|---|---|
Meas. Standard: | 0.02mm | Meas. Length: | 50-1250mm |
Display Resolution: | 5µm | Warranty: | 13 Months |
Power: | DC 5V | Output Signal: | TTL |
High Light: | 1250mm Absolute Linear Scale,VA10 Absolute Linear Scale,VA10 digital readout linear scale |
Length Measurement Digital Readout Metrology 1250mm Absolute Linear Scale
Product Specification
VA10 | VA11 | VA12 | VA13 | VA20 | VA21 | VA22 | VA23 | ||
Measuring Standard | Glass Scale - Grating period: 20μm (0.02mm) | ||||||||
Optical Detecting System | Transmissive Infrared System: wave length 880mm | ||||||||
Slide Carrier System | Vertical five bearings supporting system | ||||||||
Resolution | 5μm | 1μm | 5μm | 1μm | 5μm | 1μm | 5μm | 1μm | |
Measurement Travel | 50-1200mm | Every 50mm per length Specification | Not available | ||||||
1300-3000mm | Not available | Every 100mm per length Specification | |||||||
Accuracy | 50-450mm | ±3μm - ±5μm | -- | ||||||
500-800mm | ±10μm | ±5μm | ±10μm | ±5μm | -- | ||||
1050-2000mm | ±10μm | ±5μm | ±10μm | ±5μm | -- | ||||
1300-3000mm | -- | ±10μm/m | |||||||
Repeatability | 2μm (0.002mm) | ||||||||
Hystersis | 3μm (0.003mm) | ||||||||
Protection | IP 53 | ||||||||
Power supply | DC 5V ± 5% | ||||||||
Output Signal | TTL | TTL | 422 | 422 | TTL | TTL | 422 | 422 |
Installation Dimensions
VA10 / VA11 / VA12 / VA13 Series
VA20 / VA21 / VA22 / VA23 Series
Connector interface
DSUB 9PIN
PIN | TTL | 422A | ||
Signal | Cable | Signal | Cable | |
1 | —— | —— | A- | Yellow |
2 | 0V | Orange | 0V | White |
3 | —— | —— | B- | Red |
4 | GND | GND | GND | GND |
5 | —— | —— | R- | Black |
6 | A | Yellow | A | Green |
7 | 5V | Red | 5V | Brown |
8 | B | Green | B | Blue |
9 | R | Brown | R | Grey |
DIN 7PIN
PIN | Cable | TTL |
1 | Orange | 0V |
2 | —— | —— |
3 | Yellow | A |
4 | Green | B |
5 | Red | 5V |
6 | Brown | R |
7 | Ground | GND |
Case | Ground | GND |
Product Description
Advanced Optical Measuring System
The slide carrier of the VS / VA series scales, use a five bearing design and six spring for optical grating linear transducer, make sure the VA scales not effected by installation, the spring can adjust the angle when the operator install not good for the alignment.
The reader head still in the best way fir on the grating glass, the accuracy of VA scale is totally different with the GS or other brand in China mainland.
VA scale has a small PCB inside the 9 PIN connector, the laser compensation data is store inside, with our LCD Digital display unit, the compensation data will directly load the ECF file (compensation file) into the DRO, accuracy up to ±2μm.
Double Seals Design
The plastic seals of GS series scales use an innovative material to offer superior oil resistance, high elastic recovery properties and durability, carefully designed lips geometry offer low slide resistance.
100% Laser calibration
All glass grating transducers are individually inspected and calibrated by our in-house laser interferometer to ensure measuring accuracy comply 100% with the specifications.
Accuracy report in QR code
Each linear scale is printed with a QR code, which is convenient for users to view the accuracy report of the factory inspection.
Contact Person: Tony
Tel: 86-15820566978
Fax: 86-756-7511215